關於 IPMI 的基礎概念請參考 https://benjr.tw/11240
ipmitool sdr , sel 的 list 與 elist 稍微不同.
sdr list | elist
SDR (Sensor Data Record)這個命令將讀取 感器數據的記錄,並顯示每個感器器其名稱,數值和狀態. 如果被使用 elist ,sensor number, entity id 以及 instance, 和 asserted discrete 裝態.
[root@localhost ~]# ipmitool sdr list CPU0 SKTOCC | 0x00 | ok CPU1 SKTOCC | 0x00 | ok CPU0 PRCHT | 0x00 | ok CPU1 PRCHT | 0x00 | ok IOH THERMALERT | 0x00 | ok IOH TEMP | 42 degrees C | ok FAN FLOW TEMP | 43 degrees C | ok CPU0 DIMM TEMP | 33 degrees C | ok CPU1 DIMM TEMP | 38 degrees C | ok SENSE P3V3 | 3.30 Volts | ok SENSE P5V | 4.85 Volts | ok SENSE P12V | 11.91 Volts | ok PV VCCP CPU0 | 0.92 Volts | ok PV VCCP CPU1 | 0.93 Volts | ok P1V5 DDR3 CPU0 | 1.50 Volts | ok P1V5 DDR3 CPU1 | 1.49 Volts | ok FAN TECH0 | 3960 RPM | ok FAN TECH1 | 3840 RPM | ok FAN TECH2 | 3960 RPM | ok FAN TECH3 | 3960 RPM | ok FAN TECH4 | 3960 RPM | ok FAN TECH5 | 3840 RPM | ok FAN TECH6 | 3960 RPM | ok FAN TECH7 | 3840 RPM | ok FAN TECH8 | 3960 RPM | ok FAN TECH9 | 3720 RPM | ok IOH_ERR | 0x00 | ok SEL Fullness | 2 % messages | ok Sys PWR Monitor | 0x00 | ok Watchdog | 0x00 | ok PECI CPU0 | 38 degrees C | ok PECI CPU1 | 32 degrees C | ok VGA Presence | 0x00 | ok CPU0 CATERR | 0x00 | ok CPU1 CATERR | 0x00 | ok CPU0 THERMTRIP | 0x00 | ok CPU1 THERMTRIP | 0x00 | ok IOH THERMTRIP | 0x00 | ok PCI32_SERR | 0x00 | ok PCI32_PERR | 0x00 | ok FP UID BTN | 0x00 | ok FP NMI BTN | 0x00 | ok SMI | 0x00 | ok DIMM Sensor CHA | 0x00 | ok NMI | 0x00 | ok DIMM Sensor CHB | 0x00 | ok DIMM Sensor CHC | 0x00 | ok DIMM Sensor CHD | 0x00 | ok DIMM Sensor CHE | 0x00 | ok DIMM Sensor CHF | 0x00 | ok
[root@localhost ~]# ipmitool sdr elist CPU0 SKTOCC | E1h | ok | 3.1 | Presence detected CPU1 SKTOCC | E2h | ok | 3.2 | Presence detected CPU0 PRCHT | 07h | ok | 3.1 | CPU1 PRCHT | 08h | ok | 3.2 | IOH THERMALERT | 0Ah | ok | 7.1 | IOH TEMP | 01h | ok | 7.1 | 42 degrees C FAN FLOW TEMP | 02h | ok | 29.1 | 44 degrees C CPU0 DIMM TEMP | 03h | ok | 8.1 | 33 degrees C CPU1 DIMM TEMP | 04h | ok | 8.2 | 38 degrees C SENSE P3V3 | 11h | ok | 14.1 | 3.30 Volts SENSE P5V | 12h | ok | 14.1 | 4.85 Volts SENSE P12V | 13h | ok | 14.1 | 11.91 Volts PV VCCP CPU0 | 14h | ok | 3.1 | 0.92 Volts PV VCCP CPU1 | 15h | ok | 3.2 | 0.93 Volts P1V5 DDR3 CPU0 | 16h | ok | 7.1 | 1.50 Volts P1V5 DDR3 CPU1 | 17h | ok | 7.2 | 1.49 Volts FAN TECH0 | 21h | ok | 29.1 | 3960 RPM FAN TECH1 | 22h | ok | 29.2 | 3840 RPM FAN TECH2 | 23h | ok | 29.3 | 4080 RPM FAN TECH3 | 24h | ok | 29.4 | 3960 RPM FAN TECH4 | 25h | ok | 29.5 | 3960 RPM FAN TECH5 | 26h | ok | 29.6 | 3840 RPM FAN TECH6 | 27h | ok | 29.7 | 3960 RPM FAN TECH7 | 28h | ok | 29.8 | 3840 RPM FAN TECH8 | 29h | ok | 29.9 | 3960 RPM FAN TECH9 | 2Ah | ok | 29.10 | 3720 RPM IOH_ERR | 63h | ok | 7.1 | SEL Fullness | E7h | ok | 9.80 | 2 % messages Sys PWR Monitor | E8h | ok | 7.6 | Watchdog | E9h | ok | 7.7 | PECI CPU0 | 0Bh | ok | 3.0 | 42 degrees C PECI CPU1 | 0Ch | ok | 3.1 | 32 degrees C VGA Presence | EAh | ok | 31.1 | Present CPU0 CATERR | 61h | ok | 3.1 | CPU1 CATERR | 62h | ok | 3.2 | CPU0 THERMTRIP | 05h | ok | 3.1 | CPU1 THERMTRIP | 06h | ok | 3.2 | IOH THERMTRIP | 09h | ok | 7.1 | PCI32_SERR | 64h | ok | 48.1 | PCI32_PERR | 65h | ok | 48.1 | FP UID BTN | E3h | ok | 12.1 | FP NMI BTN | E4h | ok | 12.1 | SMI | E5h | ok | 7.1 | DIMM Sensor CHA | 66h | ok | 8.1 | NMI | E6h | ok | 7.1 | DIMM Sensor CHB | 67h | ok | 8.1 | DIMM Sensor CHC | 68h | ok | 8.1 | DIMM Sensor CHD | 69h | ok | 8.1 | DIMM Sensor CHE | 6Ah | ok | 8.1 | DIMM Sensor CHF | 6Bh | ok | 8.1 |
sel list | elist
當不使用參數或是 list 時將顯示 sel (System Event Log) 系統事件日誌的全部內容.如果被使用 elist(extended list),顯示每個事件的傳感器的 sensor ID 將轉換 Sensor Data Record.
[root@localhost ~]# ipmitool sel list 1 | 07/05/2017 | 03:17:25 | Processor #0xe2 | Presence detected | Asserted 2 | 07/05/2017 | 03:17:30 | Temperature #0x0c | Upper Non-critical going high | Asserted 3 | 07/05/2017 | 03:17:30 | Temperature #0x0c | Upper Critical going high | Asserted 4 | 07/05/2017 | 03:17:32 | Temperature #0x0c | Upper Critical going high | Deasserted 5 | 07/05/2017 | 03:17:32 | Temperature #0x0c | Upper Non-critical going high | Deasserted 6 | 07/05/2017 | 03:17:33 | Entity Presence #0xea | Present | Asserted 7 | 07/05/2017 | 03:17:35 | Processor #0xe1 | Presence detected | Asserted 8 | 07/05/2017 | 03:17:40 | Temperature #0x0b | Upper Non-critical going high | Asserted 9 | 07/05/2017 | 03:17:40 | Temperature #0x0b | Upper Critical going high | Asserted a | 07/05/2017 | 03:17:42 | Temperature #0x0b | Upper Critical going high | Deasserted b | 07/05/2017 | 03:17:42 | Temperature #0x0b | Upper Non-critical going high | Deasserted
[root@localhost ~]# ipmitool sel elist 1 | 07/05/2017 | 03:17:25 | Processor CPU1 SKTOCC | Presence detected | Asserted 2 | 07/05/2017 | 03:17:30 | Temperature PECI CPU1 | Upper Non-critical going high | Asserted | Reading 144 > Threshold 81 degrees C 3 | 07/05/2017 | 03:17:30 | Temperature PECI CPU1 | Upper Critical going high | Asserted | Reading 144 > Threshold 89 degrees C 4 | 07/05/2017 | 03:17:32 | Temperature PECI CPU1 | Upper Critical going high | Deasserted | Reading 33 > Threshold 89 degrees C 5 | 07/05/2017 | 03:17:32 | Temperature PECI CPU1 | Upper Non-critical going high | Deasserted | Reading 33 > Threshold 81 degrees C 6 | 07/05/2017 | 03:17:33 | Entity Presence VGA Presence | Present | Asserted 7 | 07/05/2017 | 03:17:35 | Processor CPU0 SKTOCC | Presence detected | Asserted 8 | 07/05/2017 | 03:17:40 | Temperature PECI CPU0 | Upper Non-critical going high | Asserted | Reading 145 > Threshold 81 degrees C 9 | 07/05/2017 | 03:17:40 | Temperature PECI CPU0 | Upper Critical going high | Asserted | Reading 145 > Threshold 89 degrees C a | 07/05/2017 | 03:17:42 | Temperature PECI CPU0 | Upper Critical going high | Deasserted | Reading 37 > Threshold 89 degrees C b | 07/05/2017 | 03:17:42 | Temperature PECI CPU0 | Upper Non-critical going high | Deasserted | Reading 37 > Threshold 81 degrees C
沒有解決問題,試試搜尋本站其他內容